Winland Electronics, Inc. Account Login, Winland Electronics, Inc. Site Map
Corporate Information, Winland Electronics, Inc.Manufacturing and Design Services, Winland Electronics, Inc.Security Products, Winland Electronics, Inc. InvestorsContact Winland Electronics, Inc.
Vehicle-Alert Standard System (VAL-1)

[PN# N/A] Status: Unavailable

Driveway warning system's enhanced module does it all.


The model VAL-1 operates on 10-14 VDC and has a form C relay output that can be connected to alarm panels, bells, dialers, etc. Unit also includes internal alarm buzzer with silence.


Download PDF Cut Sheet

Download PDF Owners Manual

Vehicle Detection
Currently this product is unavailable in the European Union. Please watch for an announcement from Winland Electronics or check back here periodically to find any change in status.

Typical Applications:

  • Residential
  • Vacation Homes
  • Farms or Ranches
  • Warehouse Building
  • Greenhouses areas
  • Storage lots
  • Private Drives

Features:

  • Electronic controlled design
  • 10- 14 VDC powered
  • Two-zone monitoring capablity
  • Exit delay timer
  • Provides (2) SPDT output - one for each zone
  • Built-in audiable alarm
  • Easy surface mount installation
  • One year parts and labor; subject to conditions of limited warranty.

Accessory Options:

  • Complete standard Vehicle-Alert system - P/N 1172
    Includes: Console, probe, 100 ft cable & transformer.
  • Vehicle-Alert Console and Transformer - P/N 1173
  • Vehicle-Alert Console - P/N 1170
  • 100 foot cable & Probe - P/N 1012
  • 10 foot cable & Probe - P/N 1012-01
  • 200 foot cable & Probe - P/N 1012-02
  • 350 foot cable & Probe - P/N 1012-03
  • 500 foot cable & Probe - P/N 1012-05
  • 1000 foot cable & Probe - P/N 1012-10
  • Additional Cable - P/N W1005
  • Splice Kit - P/N 1082
  • Remote Annunciator (12 VDC) - P/N 1175
  • Plastic 3-gang SMT electrical Box - P/N 1110
  • Metal 3-gang SMT electrical Box - P/N L-018-0001
  • Wall Transformer P/N 1111
    Voltage: 110 VAC - 12VDC regulated, 300mA.

Specifications:

  • Power Requirements: Regulated 10-14 VDC @ 100 mA
  • Current Draw (No accessories): Resting: 40 mA « Alarm: 70 mA
  • Buzzer Duration: 1 to 18 seconds
  • Buzzer Sound Pressure Level: 88 db minimum @ 30 cm @ 12 VDC
  • Exit Delay: Fixed @ 6 minutes
  • Outputs: 2 SPST relay outputs
  • Output Rating: 500 mA
  • Console Size: 6.55" x 4.70" x 1" (16.6 cm x 11.9 cm x 2.5 cm)
  • Operating Temperature: 32ç to +130ç F (0ç to +54ç C)
  • Weight (Console, probe, 100' cable & transformer): 5.8 pounds
    (2.63 Kg)
  • Cable Type: Direct burial 22 AWG shielded twisted pair with ground wire
  • Maximum Cable Length: 2500 ft. (762.5 meters)
  • Maximum Number of Probes: 2
  • Alarm Console Mounting: Mounts to 3-gang electrical box

 

* NOTE: For assistance in ordering our products , please contact our customer service staff by phone, fax or email.