Electronic Temp Alert (UTA-1)
[PN# **DISCONTINUED**]
Part #1201. Compact electronic Temp alert with professional appearance - Microprocessor controlled.
The model UTA-1 operates from 12V DC, features a professional appearance with large LCD display and separately adjustable high and low set points. Standard unit monitors temperature from +32 to +130 deg F (0 to 55 deg C). Optional probes are available for wider temperature ranges. If the monitored temperature exceeds the programmed set point, a SPST relay output is activated. The UTA-1 includes a 0-99 minute delay timer to prevent false alarms from brief variations in the temperature.
This model has been discontinued. Please use the EnviroAlert EA200 as a replacement. |
|
Typical Applications:
- Residential or Vacation Homes
- Commercial Buildings
- Office and Computer Areas
- Unattended Buildings
- Greenhouses & Animal Buildings
- Freezers and Refrigerated Rooms
- Buildings with Controlled Climates
|
Features:
- Microprocessor-controlled design
- 12 VDC powered
- Single-zone, independently adjustable high and low set points
- Large LCD display read in F or C
- Provides (2) SPST output
- Supervise remote sensor probes up to 500 ft
- Easy surface mount installation
- One year parts and labor; subject to conditions of limited warranty.
|
Accessory Options:
- Standard Temp. probe (no cable. Not for freezers or coolers) P/N 1106
Temp Range: +32 to +220 deg F (0 to +105 deg C).
- Sub-Zero Temp. probe P/N M-001-0014
Temp Range: -120 to +32 deg F (-85 to 0 deg C).
- Low Temp. Sensor probe for coolers, etc. (15 ft. cable)
P/N 1107
Temp Range: -67 to +220 deg F (-55 to +105 deg C).
- High Temp. Sensor probe for hot & dry areas. (6 ft. cable)
P/N 1108
Temp Range: -67 to +300 deg F (-55 to +149 deg C).
- High/Low Liquid Temp. Sensor probe. (3 ft. cable) P/N 1109
Temp Range: -67 to +300 deg F (-55 to +149 deg C).
- 1/2" NTP Thread Temp. probe. (3 ft. cable) P/N 1109A
Temp Range: -67 to +300 deg F (-55 to +149 deg C).
- Audible Alarm Module (Model BZ-1) P/N 1175
Voltage: 12VDC @ 8mA.
- Wall Transformer P/N 1111
Voltage: 110 VAC - 12VDC regulated, 300mA.
|
Specifications:
- Control Unit Display Range (Maximum): -120 to +300 F (-85 to +148 C)
- Low or High Limit Adjust Range *: Sensor Dependent
- Recommended Sensor Cable: 18 - 24 AWG twisted Pair (shielded or unshielded)
- Minimum Span (Rec. dist. between high & low set points.): 4 F (2.2 C)
- Temp/RH Accuracy of Probes:+/-3 F (+/-1.7 C) For Probes #1106, 1107, 1108
+/-0.5 F (+/-0.28 C) For Probes #1109, 1109A. M-001-0014
+/- 5% RH for HA-III Humidity Sensor
- Temp/RH Response Time: Sensor Dependent
- Temp/RH Sensing Element: Linear Transducer
- Outputs (not for high voltage use): 2 SPST relays
- Contact Output Rating: 1 Amp @ 30 VDC ‚ 1 AMP @ 30 VAC 50-60 Hz (not for direct high voltage switching)
- Input Voltage Requirements: 12 VDC @ 75 mA
- Control Box Material: ABS
- Dimensions & Weight: 4.5" x 3.25" x 1" (11.4 cm x 8.3 cm x 2.5 cm) ‚
8 oz. (227 g)
- Mounting: Surface Mount
|
* NOTE: For assistance in ordering our products, please contact our customer service staff by phone, fax or email.
|
|