Digital Temp-Alert (TA-2HLD)
[PN# ** DISCONTINUED **]
Part #M-001-0001. Single zone electronic Temp alert with professional appearance - Microprocessor controlled.
The model TA-2HLD operates from 12, 24V AC/DC, features a professional appearance with large LCD display and separately adjustable high and low set points. Standard unit monitors temperature from +32 to +130 deg F (0 to 55 deg C). Optional probes are available for wider temperature ranges. (see Accessory Options) If the monitored temperature rises above the high set point, a SPST relay output is activated. If the monitored temperature falls below the low set point, a SPST relay output is activated. Unit includes a 0-99 minute delay timer.
This model has been discontinued. Please use the EnviroAlert EA200 as a replacement.
|
|
Typical Applications:
- Residential or Vacation Homes
- Commercial Buildings
- Office and Computer Areas
- Unattended Buildings
- Greenhouses & Animal Buildings
- Freezers and Refrigerated Rooms
- Buildings with Controlled Climates
|
Accessory Options:
- Standard Temp. probe (no cable. Not for freezers or coolers) P/N 1106
Temp Range: +32 to +220 deg F (0 to +105 deg C).
- Sub-Zero Temp. probe P/N M-001-0014
Temp Range: -120 to +32 deg F (-85 to 0 deg C).
- Low Temp. Sensor probe for coolers, etc. (15 ft. cable) P/N 1107
Temp Range: -67 to +220 deg F (-55 to +105 deg C).
- High Temp. Sensor probe for hot & dry areas. (6 ft. cable) P/N 1108
Temp Range: -67 to +300 deg F (-55 to +149 deg C).
- High/Low Liquid Temp. Sensor probe. (3 ft. cable) P/N 1109
Temp Range: -67 to +300 deg F (-55 to +149 deg C).
- 1/2" NTP Thread Temp. probe. (3 ft. cable) P/N 1109A
Temp Range: -67 to +300 deg F (-55 to +149 deg C).
- Audible Alarm Module (Model BZ-5) P/N 1183
Voltage: 5VDC @ 3mA.
- 3 Gang Surface Mounting Box P/N L-18-1
- Wall Transformer P/N 1111
Voltage: 110 VAC - 12VDC regulated, 300mA.
|
Specifications:
- Control Unit Display Range (Maximum): -120 to +300 F (-85 to +148 C)
- Low Limit Adjust Range *: Sensor Dependent
- High Limit Adjust Range *: Sensor Dependent
- Recommended Sensor Cable: 18 - 24 AWG twisted Pair (shielded or unshielded)
- Minimum Span (Rec. dist. between high & low set points.): 4 F (2.2 C)
- Temp/RH Accuracy of Probes: +/-3 F (+/-1.7 C) For Probes #1106, 1107, 1108
+/-0.5 F (+/-0.28 C) For Probes #1109, 1109A.
M-001-0014
+/- 5% RH for #1128 HA-III Humidity Sensor
- Temp/RH Accuracy of Control Unit: £ 2%
- Temp/RH Response Time: Sensor Dependent
- Temp/RH Sensing Element: Linear Transducer
- Inputs: 1
- Outputs (not for high voltage use): 2 SPDT relays
- Contact Output Rating: 1 Amp @ 30 VDC (not for direct high voltage switching)
- Input Voltage Requirements: 12, 24 VDC @ 75 mA - 12, 24 VAC @ 125 mA
- Control Box Material: ABS
- Weight: 1 Pound (0.45 kg)
- Dimensions: 6.55" x 4.70" x 1" (16.6 cm x 11.9 cm x 2.5 cm)
- Mounting: Surface Mount or 3-gang box (#1110) 3 gang surface mount box
|
* NOTE: For assistance in ordering our products, please contact our customer service staff by phone, fax or email.
|